TA-500 Loop Sealant
Specifications Sheet

 
Composition
TA-500 loop sealant is a single component, asphaltic emulsion sealant, designed to fill and seal INDUCTIVE LOOP "SLOTS."  TA-500 loop sealant comes ready to use, requiring only stirring prior to use.  Partial containers may be re-used if container lid is properly secured after use.  TA-500 is "POLYMER" modified, for greater flexibility, and adhesion in both asphalt, or concrete "SLOTS."
-

Specifications

TA-500 Loop Sealant MEETS OR EXCEEDS THE STATE OF CALIFORNIA SPECIFICATION (CALTRANS) #8040-41A-15, for ASPHALITIC EMULSION SEALANTS.
-

Surface Preparation

"SLOTS" shall be free of dust, debris, and water prior to the application of TA-500 loop sealant.  The use of an "air-jet" is recommended to achieve the above.  "SLOTS" that are slightly damp or moist are recommended to assure desired penetration, and adhesion of TA-500 loop sealant in the "SLOT."
-

Application

Mix TA-500 loop sealant thoroughly prior to use (when using a mechanical mixer, avoid over mixing, as this may entrain air into the "SLOT," and result in voids in the cured seal).  TA-500 loop sealant can be poured directly from the container, or poured into any other suitable applicator.  Apply TA-500 loop sealant directly into the "SLOTS" and immediately "strike-off" using our easy to handle "V" shape squeegee.  This procedure will reduce waste, and assure that the "SLOT" is properly filled.
-

Coverage

TA-500 loop sealant will fill, and seal approximately 30 linear feet of 1/4" x 2" "SLOTS" per gallon.  This will vary depending on width/depth of the "SLOT," as well as application technique.

-

Dry/Cure Time

Dry-time is approximately 5 to 10 minutes in warm weather (70 degrees f.).  This is the time required prior to vehicle traffic.  For earlier traffic, cover TA-500 loop sealant with a "Fine" dry sand.  Dry-time will vary depending on weather conditions, and the amount of TA-500 loop sealant on the permanent surface.

Cure-time will depend greatly on the width/depth of the "SLOTS" filled, and weather conditions.  TA-500 loop sealant may feel soft to the touch for several days after application, without affecting the final results.  TA-500 loop sealant cures by evaporation of water, unlike the "chemical cure" of other systems.

-

Clean-Up

Water can be used to clean TA-500 loop sealant from tools, and equipment, prior to drying.  A suitable petroleum solvent is required to remove dried product.  Heavy residue can be removed with the use of a "steel" scraper prior to using solvent.
-

Packaging

TA-500 loop sealant is available in 5-gallon plastic pails.
-

Precautions

Do not store in direct sunlight, or in temperatures above 100 degrees f.    TA-500 loop sealant shall not be applied during or when rain is imminent.  Application temperatures shall be 40 degrees f. and rising.  Do not dilute or alter TA-500 loop sealant , use as received.  Protect from freezing.

 

 

 
 
 