TA-500 Loop Sealant
Specifications Sheet
|
|
|
| Composition |
| TA-500 loop sealant is a single
component, asphaltic emulsion sealant, designed to fill and seal
INDUCTIVE LOOP "SLOTS." TA-500 loop sealant comes ready to use,
requiring only stirring prior to use. Partial containers may
be re-used if container lid is properly secured after use.
TA-500 is "POLYMER" modified, for greater flexibility, and
adhesion in both asphalt, or concrete "SLOTS." |
| - |
|
Specifications |
| TA-500 Loop Sealant MEETS OR EXCEEDS
THE STATE OF CALIFORNIA SPECIFICATION (CALTRANS) #8040-41A-15, for
ASPHALITIC EMULSION SEALANTS. |
| - |
|
Surface Preparation |
| "SLOTS" shall
be free of dust, debris, and water prior to the application of
TA-500 loop sealant. The use of an "air-jet" is recommended to
achieve the above. "SLOTS" that are slightly damp or
moist are recommended to assure desired penetration, and adhesion of
TA-500 loop sealant in the "SLOT." |
| - |
|
Application |
| Mix TA-500 loop sealant thoroughly
prior to use (when using a mechanical mixer, avoid over mixing, as
this may entrain air into the "SLOT," and result in voids
in the cured seal). TA-500 loop sealant can be poured directly from the
container, or poured into any other suitable applicator. Apply
TA-500 loop sealant directly into the "SLOTS" and immediately
"strike-off" using our easy to handle "V" shape
squeegee. This procedure will reduce waste, and assure that
the "SLOT" is properly filled. |
| - |
|
Coverage |
| TA-500 loop sealant will fill, and
seal approximately 30 linear feet of 1/4" x 2"
"SLOTS" per gallon. This will vary depending on
width/depth of the "SLOT," as well as application
technique. |
|
- |
|
Dry/Cure Time |
| Dry-time is approximately
5 to 10 minutes in warm weather (70 degrees f.). This is the
time required prior to vehicle traffic. For earlier traffic,
cover TA-500 loop sealant with a "Fine" dry sand. Dry-time will
vary depending on weather conditions, and the amount of TA-500 loop
sealant on
the permanent surface.
Cure-time will depend greatly on the
width/depth of the "SLOTS" filled, and weather
conditions. TA-500 loop sealant may feel soft to the touch for several days
after application, without affecting the final results. TA-500
loop sealant cures by evaporation of water, unlike the "chemical cure"
of other systems. |
| - |
|
Clean-Up |
| Water can be used to
clean TA-500 loop sealant from tools, and equipment, prior to drying. A
suitable petroleum solvent is required to remove dried
product. Heavy residue can be removed with the use of a
"steel" scraper prior to using solvent. |
| - |
|
Packaging |
| TA-500 loop sealant is available in
5-gallon plastic pails. |
| - |
|
Precautions |
| Do not store in direct
sunlight, or in temperatures above 100 degrees f.
TA-500 loop sealant shall not be applied during or when rain is imminent.
Application temperatures shall be 40 degrees f. and rising. Do
not dilute or alter TA-500 loop sealant , use as received. Protect from
freezing.
|
| |
|
|
|
| |
|
|
|
|
|
|
R.Hart Sales, LLC |
|
PO Box 672 |
|
San Marcos, TX 78666 |
|
Phone: 512-396-7428 /
Fax: 512-396-7417 |
|
Copyright © 2000
R. Hart
Sales, All Rights Reserved |
|
|
| |
|